About 282,000 results
Open links in new tab
  1. What exactly are harmonics and how do they "appear"?

    May 21, 2012 · "how are harmonics generated? The signal is just "on" or "off", how are there first, third, and fifth harmonics and why do they get weaker?" // Although not a satisfactory answer, …

  2. How do I calculate THD? - Electrical Engineering Stack Exchange

    Apr 24, 2024 · I want to calculate the total harmonic distortion of the signal using this graph and formula. The formula is taken from this page: Calculating harmonic distortion First Question: …

  3. filter - What is the harmonic content of a PWM signal? - Electrical ...

    To properly design a filter for this application to hit a specific harmonic distortion target, I need to know the harmonic content of the PWM signal. How can I predict what that harmonic content is?

  4. Coefficients and harmonics of a PWM signal

    Apr 20, 2018 · Basically, a PWM signal is created using the fundamental harmonic and it's odd order harmonics. F_fundamental = 100kHz. F_3= 3*100kHz. F_5= 5*100kHz... This happens …

  5. What is the best approach for reducing harmonic distortion?

    Dec 15, 2013 · Where are you having issues with Harmonic Distortion in relation to your converter driven machines? Upstream in your power distribution system or after the converter? It sounds …

  6. harmonics - Fundamental vs true RMS values - Can the …

    Jan 10, 2022 · Here is a practical situation: We are measuring harmonics with a Class-A PQ device. At certain times we have the fundamental values of current higher than the true RMS …

  7. Why don't we use the third harmonic in power transmission?

    Aug 5, 2023 · And the whole thing is even further complicated by loads that either abuse the harmonic content (nonlinear loads like rectifiers), or literally don't know what to do with it (the …

  8. Help me understand FFT and harmonic distortions - Electrical ...

    Jan 9, 2015 · I'm new to FFT and harmonic distortions. I'm dealing with a power system where the phase currents are distorted. Now I don't understand the concept of FFT and why the …

  9. signal - Harmonic detection using lock-in amplifier - Electrical ...

    May 3, 2019 · 0 Can a third harmonic of a signal be detected using a lock-in amplifier under the same parameters fixed for collecting the fundamental or the parameters needs to be …

  10. Filter design according to harmonics in an inverter

    Apr 17, 2024 · According to the Fourier series, when AC waves of different frequencies are added to the fundamental frequency, we can obtain waves such as square and sawtooth. When we …